
Sep 17, 2023 Newest 1z0-996-22 Exam Dumps – Achieve Success in Actual 1z0-996-22 Exam
Updated Oracle 1z0-996-22 Dumps – Check Free 1z0-996-22 Exam Dumps (2023)
NEW QUESTION # 38
A device has one or more measuring components that measure consumption, demand, or other values.
Which lists two attributes of a measuring component?
- A. Channel Multiplier and Channel ID
- B. Manufacturer and Model
- C. Model and Serial Number
- D. Serial Number and Badge Number
- E. Channel ID and Badge Number
Answer: D
NEW QUESTION # 39
What can cause multiple bill lines for a rate component to be produced in a bill calculation header?
- A. change in Rate Schedule
- B. change in Rate Version Calculation Group
- C. changes in Rate Version Calculation Group and Bill Factor
- D. changes in Rate Schedule and Bill Factor
- E. change in Bill Factor
Answer: D
NEW QUESTION # 40
Within the application, operational devices can be assets or components.
Which two statements are true about components? (Choose two.)
- A. Components can be installed at locations.
- B. Components can't have specifications.
- C. Components are attached to assets.
- D. Components are not a class of assets.
- E. Components have a disposition that tracks their location and status.
Answer: A,C
NEW QUESTION # 41
Which three statements are true about the different types of measuring components? (Choose three.)
- A. The measuring component types are physical, standalone, scratchpad, and TOU.
- B. Scalar measuring components contain a single measurement for an arbitrary period of time.
- C. Seconds-per-interval (SPI) is one of the attributes of scalar measuring components.
- D. Only physical measuring components reference a device configuration.
- E. The terms register and channel are synonyms for measuring component.
Answer: A,B,E
NEW QUESTION # 42
Which option correctly describes the high-level process from loading measurements through calculating usage?
- A. 1. Load Initial Measurements
2. Verify, evaluate, and enter Initial Measurements
3. Create Final Measurements
4. Calculate Usage - B. 1. Load Initial Measurements
2. Validate, evaluate, and estimate Initial Measurements
3. Update Initial Measurements
4. Calculate Usage - C. 1. Load Initial Measurements
2. Validate, edit, and estimate Initial Measurements
3. Create Final Measurements
4. Calculate Usage - D. 1. Load Initial Measurements
2. Validate, edit, and estimate Initial Measurements
3. Create Final Measurements
4. Update Initial Measurements
Answer: A
NEW QUESTION # 43
What correctly describes the order in which algorithms, if plugged in, are executed when a bill changes from the "Pending" state to the "Complete" state?
- A. Service Agreement Type - Pre-Bill Completion; Customer Class - Pre-Bill Completion; Service Agreement Type - Bill Completion; Customer Class - Bill Completion; Customer Class - Post-Bill Completion
- B. Customer Class - Pre-Bill Completion; Service Agreement Type - Pre-Bill Completion; Customer Class - Bill Completion; Service Agreement Type - Bill Completion; Customer Class - Post-Bill Completion
- C. Service Agreement Type - Pre-Bill Completion; Customer Class - Pre-Bill Completion; Service Agreement Type - Bill Completion; Customer Class - Bill Completion; Service Agreement Type - Post-Bill Completion; Customer Class - Post-Bill Completion
- D. Service Agreement Type - Pre-Bill Completion; Service Agreement Type - Bill Completion; Customer Class - Pre-Bill Completion; Customer Class - Bill Completion; Customer Class - Post-Bill Completion
- E. Customer Class - Pre-Bill Completion; Customer Class - Bill Completion; Service Agreement Type - Pre- Bill Completion; Service Agreement Type - Post-Bill Completion
Answer: A
NEW QUESTION # 44
What happens when a device's measuring components are reconfigured (a new measuring component will be read) at a service point?
- A. A new installation event is created to "install" (new device configuration).
- B. The original installation event is updated with the "removal" (expire old device configuration).
- C. A device with a new configuration type is created.
- D. The original installation event is updated with the "removal" (expire old device configuration) and a new installation event is created to "install" (new device configuration).
- E. A device with a new configuration type is created. Moreover, a new installation event is created to 'install" (new device configuration).
Answer: D
NEW QUESTION # 45
How should you configure the derived values that are relevant for a device?
- A. Configure the derived values on the Final Measurement Type for the measuring components to be defined on the device.
- B. Configure the derived values on the Measuring Component Type for the measuring components to be defined on the device.
- C. Configure the derived values on the Device Type for the derived values to be defined on the device.
- D. Configure the derived values on the Measuring Component for the measuring components to be defined on the device.
Answer: A
NEW QUESTION # 46
On which three entities can proration be disabled? (Choose three.)
- A. Rate Version Calculation Group
- B. Calculation Rule
- C. Calculation Rule Business Object
- D. Bill Factor
- E. Rate Schedule
Answer: A,C,E
NEW QUESTION # 47
Throughout its lifecycle, an asset's disposition changes as it is moved between locations and service statuses.
Which are valid asset dispositions?
- A. Receiving; Installed; Storage; Retired
- B. In Receipt; In Field; In Stores; Retired
- C. In Receipt; Installed; In Stores; Retired
- D. Receiving; In Field; Storage; Retired
Answer: B
NEW QUESTION # 48
There has been a meter exchange at a service point in the past year.
How many installation events exist for the service point for the past year?
- A. Four
- B. Two
- C. Three
- D. None
- E. One
Answer: E
NEW QUESTION # 49
Your implementation requires an installation of two types of devices:
Electric Smart Meter
Gas Manual Meter
Which two Device Type attributes are required to identify these device types? (Choose two.)
- A. Device Business Object
- B. Valid Measuring Component Types
- C. Serial Number
- D. Service Type
- E. Manufacturer
Answer: B,D
NEW QUESTION # 50
Which three statements are correct for Adjustment Types? (Choose three.)
- A. They control the valid Service Agreement Types that adjustments can be linked to.
- B. They control the valid Adjustment Profiles that adjustment types can belong to.
- C. They control how adjustments appear on bills.
- D. They control whether a rate is to be called to calculate an adjustment amount.
- E. They can default an Adjustment Amount to adjustments.
Answer: A,C,D
NEW QUESTION # 51
Which relationship must be established with an external system or a service provider before creating bill determinants?
- A. Usage Transaction
- B. Usage Rule
- C. Usage Factor
- D. Usage Subscription
Answer: D
NEW QUESTION # 52
How many bill segment-related financial transactions do Payment Arrangements have?
- A. unlimited
- B. none
- C. depends on the number of bills that will contain the customer's payment arrangement details
- D. depends on the number of payments that are part of the payment arrangement
- E. one
Answer: E
Explanation:
Reference:
20Bill%20Customers/4.2.2.12%20CCB.v2.4.Manage%20Payment%20Arrangement%20Charges.pdf (14)
NEW QUESTION # 53
When a customer has a specific price for a defined quantity which is different to other customers, where is this specific price for the related Bill Factor defined?
- A. Account Characteristic
- B. Bill Factor Value
- C. Service Agreement - Contract Value
- D. Bill Factor Characteristic
- E. Calculation Rule
Answer: C
NEW QUESTION # 54
Which configuration steps are required to derive loss-adjusted kWh on a measuring component based on a loss factor value related to a service point?
- A. Configure a Service Point Characteristic Type and derivation algorithm, and then associate the algorithm to the Measuring Component Type and the characteristic value to the service point.
- B. Configure a factor and derivation algorithm, and then associate the factor to the Measuring Component Type and the derivation algorithm to the service point.
- C. Configure a factor and derivation algorithm, and then associate both to the Measuring Component Type and service point.
- D. Configure a Service Point Characteristic Type, factor, derivation algorithm, and Service Quantity Identifier (SQI), and then associate the SQI and derivation algorithm to the Measuring Component Type and the characteristic value to the service point.
- E. Configure an SQI and the derivation algorithm, and then associate the algorithm to the Measuring Component Type and SQI to the service point.
Answer: E
NEW QUESTION # 55
For a customer to receive a Subscription communication, what must they have?
- A. an active address type preference
- B. an active account contact preference
- C. an active address contact preference
- D. an active person contact preference
Answer: B
NEW QUESTION # 56
......
Actual 1z0-996-22 Exam Recently Updated Questions with Free Demo: https://actual4test.practicetorrent.com/1z0-996-22-practice-exam-torrent.html